Warmboard’s channels are sized to hold 16 mm PEX-AL-PEX pipe firmly, flush with the panel surface. The pipe is laid at 300 mm spacing, set by the channels.
Use the pipe specified in your plan set. Other pipe types can tick as the heating cycles, when the pipe’s outer layer rubs against the channel.
How it fits together
Manifolds
Each manifold sends water to its pipe loops and back, with flow meters and balance valves, and an actuator on each zone. It mounts in a wall cavity behind an access door.
Loops and zones
The pipe loop plan sets each loop’s length and route and the manifold positions. Don’t move a manifold without checking with us: its distance from the heat source sets the pipe sizes.
Licensed plumber
A licensed plumber lays the pipe, makes every connection at the manifolds and pressure-tests the system before the floor covering goes down.
Installation
Marking out, custom routes, laying the pipe, manifolds and pressure testing.